Line 1: Line 1:
(a)The Fourier transform of X(jw) of a continuous-time signal x(t) is periodic
+
(a) The FT of <math>X(j\omega)</math> of a continuous-time signal x(t) is periodic
  MAY BE: X(jw) is periodic only if x(t) is periodic
+
  MAY BE: <math>X(j\omega)</math> is periodic only if x(t) is periodic
  
(b)The Fourier transform of X(ejw) of a continuous-time signal x[n] is periodic
+
(b) The FT of <math>X(e^{j\omega})</math> of a continuous-time signal x[n] is periodic
  YES: X(ejw) is always periodic with period 2pi
+
  YES: <math>X(e^{j\omega})</math> is always periodic with period <math>2\pi</math>
  
(c)If the FT of X(ejw) of a discrete-time signal x[n] is given as: X(ejw) = 3 + 3cos(3w), then the signal x[n] is periodic
+
(c) If the FT of <math>X(e^{j\omega})</math> of a discrete-time signal x[n] is given as: <math>X(e^{j\omega}) = 3 + 3cos(3\omega)</math>, then the signal x[n] is periodic
 
  MAY BE:
 
  MAY BE:
  
(d)If the FT of X(jw) of a continuous-time signal x(t) consists of only impulses, then x(t) is periodic
+
(d) If the FT of <math>X(j\omega)</math> of a continuous-time signal x(t) consists of only impulses, then x(t) is periodic
  MAY BE: e^jw0n has a FT that is an impulse
+
  MAY BE: <math>e^{j\omega_0n}</math> has a FT that is an impulse
  
(e)Lets denote X(jw) the FT of a continuous-time non-zero signal x(t).  If x(t) is an odd signal, then  
+
(e) Lets denote <math>X(j\omega)</math> the FT of a continuous-time non-zero signal x(t).  If x(t) is an odd signal, then:
 
<math>\int_{-\infty}^{\infty} X(j\omega) d\omega = 0 </math>
 
<math>\int_{-\infty}^{\infty} X(j\omega) d\omega = 0 </math>
  YES: this eqation is the same as <math>\int_{-\infty}^{\infty} X(j\omega) e^{-j\omega_0t}d\omega = 0</math> where t = 0. From this we can conclude that x(0) = 0, which holds true for odd signals.
+
  YES: this equation is the same as <math>\int_{-\infty}^{\infty} X(j\omega) e^{-j\omega_0t}d\omega = 0</math> where t = 0.  
 +
From this we can conclude that x(0) = 0, which holds true for odd signals.
  
(f)Lets denote X(jw) the FT of a continuous-time non-zero signal x(t).  If x(t) is an odd signal, then  
+
(f) Lets denote <math>X(j\omega)</math> the FT of a continuous-time non-zero signal x(t).  If x(t) is an odd signal, then:
 
<math>\int_{-\infty}^{\infty} |X(j\omega)|^2 d\omega = 0 </math>
 
<math>\int_{-\infty}^{\infty} |X(j\omega)|^2 d\omega = 0 </math>
  NO: from parseval's relation, we see that <math>\int_{-\infty}^{\infty} |X(j\omega)|^2 d\omega = 0 = 2\pi \int_{-\infty}^\infty |x(t)|^2 dt </math> The integral of the magnitude squared will allways be positive for an odd signal.
+
  NO: using parseval's relation, we see that: <math>\int_{-\infty}^{\infty} |X(j\omega)|^2 d\omega = 0 = 2\pi \int_{-\infty}^\infty |x(t)|^2 dt </math>  
 +
The integral of the magnitude squared will always be positive for an odd signal.
 +
 
 +
(g) Lets denote <math>X(e^{j0})</math> the FT of a DT signal x[n]. If <math>X(e^{j0})</math> = 0, then x[n] = 0.
 +
MAY BE: <math>X(e^{j0})</math> is simply <math>X(e^{j\omega})</math> evaluated at <math>\omega = 0</math>.
 +
This only tells you that x[0] = 0, not the entire signal x[n] = 0.
  
(g)Lets denot X(ejw) the FT of a DT signal x[n]. If X(ej0) = 0, then x[n] = 0.
 
MAY BE: X(ej0) is simply X(ejw) evaluated at w = 0. This does not tell you anything about the original signal x[n] other than x[0] = 0.
 
  
 
(h)
 
(h)
Line 26: Line 30:
  
  
(i)Let x(t) be a continuous time real-valued signal for which X(jw) = 0 when |w| > wm where wm is a real and positive number. Denote the modulated signal y(t) = x(t)c(t) where c(t) = cos(wct) and wc is a real, positive nubmer. IF wc is greater than 2wm, x(t) can be recovered from y(t).
+
(i) Let x(t) be a continuous time real-valued signal for which <math>X(j\omega)</math> = 0 when <math>|\omega| > \omega_M</math> where <math>\omega_M</math> is a real and positive number. Denote the modulated signal y(t) = x(t)c(t) where c(t) = <math>cos(\omega_ct)</math> and <math>\omega_c</math> is a real, positive number. If <math>\omega_c</math> is greater than <math>2\omega_M</math>, x(t) can be recovered from y(t).
  YES: Taking the FT of c(t) we get delta functions at wc and -wc. When convolved with the FT of the input signal X(jw), the function X(jw) gets shifted to wc and -wc with ranges (-wc-wm) to (-wc+wm) and (wc-wm) to (wc+wm). Therefore (wc-wm) > (-wc+wm) must hold for there to be no overlapping. This is equivalent to 2wc > 2wm => wc > wm. Since wc > 2wm, there is no overlapping and x(t) can be recovered.
+
  YES: Taking the FT of c(t) we get delta functions at <math>\omega_c</math> and <math>-\omega_c</math>.
 +
When convolved with the FT of the input signal <math>X(j\omega)</math>, the function <math>X(j\omega)</math> gets shifted to <math>\omega_c</math> and <math>-\omega_c</math>
 +
with ranges <math>(-\omega_c-\omega_M)</math> to <math>(-\omega_c+\omega_M)</math> and <math>(\omega_c-\omega_M)</math> to <math>(\omega_c+\omega_M)</math>.  
 +
Therefore <math>(\omega_c-\omega_M) > (-\omega_c+\omega_M)</math> must hold for there to be no  
 +
overlapping. This is equivalent to <math>2\omega_c > 2\omega_M  => \omega_c > \omega_M</math>. Since <math>\omega_c > 2\omega_M</math>, there is no overlapping  
 +
and x(t) can be recovered.
  
  
  
(j)Let x(t) be a continuous time real-valued signal for which X(jw) = 0 when |w| > 40pi. Denote the modulated signal y(t) = x(t)c(t) where c(t) = e{jwct} and wc is a real, positive nubmer. There is a constraint of wc to guarantee that x(t) can be recovered from y(t).
+
(j) Let x(t) be a continuous time real-valued signal for which <math>X(j\omega)</math> = 0 when <math>|\omega| > 40\pi</math>. Denote the modulated signal y(t) = x(t)c(t) where c(t) = <math>e^{j\omega_ct}</math> and <math>\omega_c</math> is a real, positive number. There is a constraint of <math>\omega_c</math> to guarantee that x(t) can be recovered from y(t).
  NO: The FT of c(t) is just a shifted delta function, which will simply shift the input signal x(t) so there is no chance of overlapping.
+
  NO: The FT of c(t) is just a shifted delta function, which will simply shift the  
 +
input signal x(t) so there is no chance of overlapping.

Revision as of 20:47, 18 July 2008

(a) The FT of $ X(j\omega) $ of a continuous-time signal x(t) is periodic

MAY BE: $ X(j\omega) $ is periodic only if x(t) is periodic

(b) The FT of $ X(e^{j\omega}) $ of a continuous-time signal x[n] is periodic

YES: $ X(e^{j\omega}) $ is always periodic with period $ 2\pi $

(c) If the FT of $ X(e^{j\omega}) $ of a discrete-time signal x[n] is given as: $ X(e^{j\omega}) = 3 + 3cos(3\omega) $, then the signal x[n] is periodic

MAY BE:

(d) If the FT of $ X(j\omega) $ of a continuous-time signal x(t) consists of only impulses, then x(t) is periodic

MAY BE: $ e^{j\omega_0n} $ has a FT that is an impulse

(e) Lets denote $ X(j\omega) $ the FT of a continuous-time non-zero signal x(t). If x(t) is an odd signal, then: $ \int_{-\infty}^{\infty} X(j\omega) d\omega = 0 $

YES: this equation is the same as $ \int_{-\infty}^{\infty} X(j\omega) e^{-j\omega_0t}d\omega = 0 $ where t = 0. 
From this we can conclude that x(0) = 0, which holds true for odd signals.

(f) Lets denote $ X(j\omega) $ the FT of a continuous-time non-zero signal x(t). If x(t) is an odd signal, then: $ \int_{-\infty}^{\infty} |X(j\omega)|^2 d\omega = 0 $

NO: using parseval's relation, we see that: $ \int_{-\infty}^{\infty} |X(j\omega)|^2 d\omega = 0 = 2\pi \int_{-\infty}^\infty |x(t)|^2 dt  $ 
The integral of the magnitude squared will always be positive for an odd signal.

(g) Lets denote $ X(e^{j0}) $ the FT of a DT signal x[n]. If $ X(e^{j0}) $ = 0, then x[n] = 0.

MAY BE: $ X(e^{j0}) $ is simply $ X(e^{j\omega}) $ evaluated at $ \omega = 0 $. 
This only tells you that x[0] = 0, not the entire signal x[n] = 0.


(h)


(i) Let x(t) be a continuous time real-valued signal for which $ X(j\omega) $ = 0 when $ |\omega| > \omega_M $ where $ \omega_M $ is a real and positive number. Denote the modulated signal y(t) = x(t)c(t) where c(t) = $ cos(\omega_ct) $ and $ \omega_c $ is a real, positive number. If $ \omega_c $ is greater than $ 2\omega_M $, x(t) can be recovered from y(t).

YES: Taking the FT of c(t) we get delta functions at $ \omega_c $ and $ -\omega_c $.  
When convolved with the FT of the input signal $ X(j\omega) $, the function $ X(j\omega) $ gets shifted to $ \omega_c $ and $ -\omega_c $
with ranges $ (-\omega_c-\omega_M) $ to $ (-\omega_c+\omega_M) $ and $ (\omega_c-\omega_M) $ to $ (\omega_c+\omega_M) $. 
Therefore $ (\omega_c-\omega_M) > (-\omega_c+\omega_M) $ must hold for there to be no 
overlapping. This is equivalent to $ 2\omega_c > 2\omega_M  => \omega_c > \omega_M $. Since $ \omega_c > 2\omega_M $, there is no overlapping 
and x(t) can be recovered.


(j) Let x(t) be a continuous time real-valued signal for which $ X(j\omega) $ = 0 when $ |\omega| > 40\pi $. Denote the modulated signal y(t) = x(t)c(t) where c(t) = $ e^{j\omega_ct} $ and $ \omega_c $ is a real, positive number. There is a constraint of $ \omega_c $ to guarantee that x(t) can be recovered from y(t).

NO: The FT of c(t) is just a shifted delta function, which will simply shift the 
input signal x(t) so there is no chance of overlapping.

Alumni Liaison

BSEE 2004, current Ph.D. student researching signal and image processing.

Landis Huffman