(9 intermediate revisions by 3 users not shown)
Line 4: Line 4:
 
[[Category:ECE438]]
 
[[Category:ECE438]]
 
[[Category:signal processing]]   
 
[[Category:signal processing]]   
 +
[[Category:Discrete-time_Fourier_transform]]
  
 
<center><font size= 4>
 
<center><font size= 4>
Line 18: Line 19:
 
<center><font size= 3>
 
<center><font size= 3>
 
Background
 
Background
</font size>
+
</font size></center>
  
 
----
 
----
Line 30: Line 31:
 
In continuous time, the signal looks like this:
 
In continuous time, the signal looks like this:
  
[[Image:Example.jpg]]
+
<center>[[Image:srhfig1.png|signal]]</center>
  
 
Using the continuous time signal, it is possible to sample the signal. Due to the Nyquist Theorem, <math>f_{s}>1760\ Hz</math>. To demonstrate sampling above the Nyquist Rate, a <math>f_{s}</math> of 2000 Hz will be used. The sampling points are shown in red on top of the original signal below
 
Using the continuous time signal, it is possible to sample the signal. Due to the Nyquist Theorem, <math>f_{s}>1760\ Hz</math>. To demonstrate sampling above the Nyquist Rate, a <math>f_{s}</math> of 2000 Hz will be used. The sampling points are shown in red on top of the original signal below
  
[[Image:Example.jpg]]
+
<center>[[Image:srhfig2.png|Sampling]]</center>
  
 
----
 
----
 
<center><font size= 3>
 
<center><font size= 3>
 
CTFT vs DTFT
 
CTFT vs DTFT
</font size>
+
</font size></center>
  
 
In order to understand what is happening in the frequency domain, we can compare the CTFT of the cosine to the DTFT of the sampled cosine.  
 
In order to understand what is happening in the frequency domain, we can compare the CTFT of the cosine to the DTFT of the sampled cosine.  
Line 46: Line 47:
  
 
<math>X(f)=\frac{\delta(f-880)+\delta(f+880)}{2}</math>
 
<math>X(f)=\frac{\delta(f-880)+\delta(f+880)}{2}</math>
 +
 +
<center>[[Image:srhfig3.png|CTFT]]</center>
  
 
To obtain the DTFT from the CTFT, three steps must occur:
 
To obtain the DTFT from the CTFT, three steps must occur:
Line 54: Line 57:
 
<center><font size= 3>
 
<center><font size= 3>
 
Sampling above the nyquist rate
 
Sampling above the nyquist rate
</font size>
+
</font size></center>
 
For the sampling at 2000Hz, this results in the following DTFT:
 
For the sampling at 2000Hz, this results in the following DTFT:
  
<math>\Chi(\omega)=2000\frac{\delta(\frac{2000 \omega}{2 \pi }-880)+\delta(\frac{2000 \omega}{2 \pi }+880)}{2}</math>
+
<math>\Chi(\omega)=2000\frac{\delta(\frac{2000 \omega}{2 \pi }-880)+\delta(\frac{2000 \omega}{2 \pi }+880)}{2}, -\pi<\omega<\pi</math>
  
<math>\Chi(\omega)=2000\frac{\delta(\frac{2000 \omega-2 \pi 880}{2 \pi })+\delta(\frac{2000 \omega+2 \pi 880}{2 \pi })}{2}</math>
+
<math>\Chi(\omega)=2000\frac{\delta(\frac{2000 \omega-2 \pi 880}{2 \pi })+\delta(\frac{2000 \omega+2 \pi 880}{2 \pi })}{2}, -\pi<\omega<\pi</math>
  
<math>\Chi(\omega)=2000\frac{\delta(2000\frac{ \omega-2 \pi \frac{880}{2000}}{2 \pi })+\delta(\frac{2000\omega+2 \pi \frac{880}{2000}}{2 \pi })}{2}</math>
+
<math>\Chi(\omega)=2000\frac{\delta(2000\frac{ \omega-2 \pi \frac{880}{2000}}{2 \pi })+\delta(\frac{2000\omega+2 \pi \frac{880}{2000}}{2 \pi })}{2}, -\pi<\omega<\pi</math>
  
  
<math>\Chi(\omega)=2\pi \frac{\delta( \omega- \pi \frac{880}{1000})+\delta(\omega+\pi \frac{880}{1000})}{2}</math>
+
<math>\Chi(\omega)=2\pi \frac{\delta( \omega- \pi \frac{880}{1000})+\delta(\omega+\pi \frac{880}{1000})}{2}, -\pi<\omega<\pi</math>
  
<math>\Chi(\omega)=\pi \delta( \omega- \pi \frac{880}{1000})+\pi \delta(\omega+\pi \frac{880}{1000})</math>
+
<math>\Chi(\omega)=\pi \delta( \omega- \pi \frac{880}{1000})+\pi \delta(\omega+\pi \frac{880}{1000}), -\pi<\omega<\pi</math>
  
 
<math>\Chi(\omega)=\left\{\begin{array}{ll}\pi \delta( \omega- \pi \frac{880}{1000})+\pi \delta(\omega+\pi \frac{880}{1000}), &  \text{ if }-\pi<\omega<\pi,\\ \text{periodic period } 2\pi\end{array} \right.  \ </math>  
 
<math>\Chi(\omega)=\left\{\begin{array}{ll}\pi \delta( \omega- \pi \frac{880}{1000})+\pi \delta(\omega+\pi \frac{880}{1000}), &  \text{ if }-\pi<\omega<\pi,\\ \text{periodic period } 2\pi\end{array} \right.  \ </math>  
  
[[Image:Example.jpg]]
+
[[Image:srhfig4.png|Sampling Above Nyquist]]
 +
 
 +
 
 
<center><font size= 3>
 
<center><font size= 3>
 
Sampling Below the Nyquist Rate
 
Sampling Below the Nyquist Rate
</font size>
+
</font size></center>
 +
 
 
We can repeat the same process for a sampling below the Nyquist rate. In this case, we will sample at 1000 Hz. Using the same process as above, the result is:
 
We can repeat the same process for a sampling below the Nyquist rate. In this case, we will sample at 1000 Hz. Using the same process as above, the result is:
  
Line 81: Line 87:
  
 
The plot of the DTFT is shown below:  
 
The plot of the DTFT is shown below:  
[[Image:Example.jpg]]
+
 
 +
<center>[[Image:srhfig5.png|Sampling Below Nyquist]]</center>
  
 
Note that the original frequency components are outside of the <math>[-\pi,\pi]</math> range. This leads to aliasing, which creates an additional frequency component at 120 Hz. This illustrates the fact that sampling below the nyquist rate will create aliasing and prevent shannnon reconstruction of the signal.
 
Note that the original frequency components are outside of the <math>[-\pi,\pi]</math> range. This leads to aliasing, which creates an additional frequency component at 120 Hz. This illustrates the fact that sampling below the nyquist rate will create aliasing and prevent shannnon reconstruction of the signal.
Line 87: Line 94:
 
<center><font size= 3>
 
<center><font size= 3>
 
Conclusion
 
Conclusion
</font size>
+
</font size></center>
----
+
As a brief overview, there are two main takeaways:
<center><font size= 3>
+
*The DTFT can be obtained from the CTFT by time scaling f by <math>2\pi/f_s</math>, magnitude scaling by <math>f_s</math>, and repeating every <math>2\pi</math>
References
+
*Sampling below the nyquist rate will cause aliasing and add low frequency components to the signal, potentially preventing any recovery. 
</font size>
+
 
----
 
----
 
----
 
----
(create a question page and put a link below)
+
==[[SRH_Slecture_Review|Questions and comments]]==
==[[slecture_title_of_slecture_review|Questions and comments]]==
+
  
If you have any questions, comments, etc. please post them on [[slecture_title_of_slecture_review|this page]].
+
If you have any questions, comments, etc. please post them on [[SRH_Slecture_Review|this page]].
 
----
 
----
[[2014_Fall_ECE_438_Boutin|Back to ECE438, Fall 2014]]
+
[[2014_Fall_ECE_438_Boutin_digital_signal_processing_slectures|Back to ECE438 slectures, Fall 2014]]

Latest revision as of 19:04, 16 March 2015


Discrete-time Fourier transform (DTFT) of a sampled cosine

A slecture by ECE student Sutton Hathorn

Partly based on the ECE438 Fall 2014 lecture material of Prof. Mireille Boutin.



Background


A cosine wave with frequency f can be written as $ cos(2 \pi f t) $. When sampling this cosine with period T (frequency $ f_{s}=1/T $, the sampled signal $ x[n] $ can be written as $ x[n]=cos(\frac{2 \pi f n}{T}) $.

The nyquist rate for a given signal is given as $ f_{s} = 2 f_{m} $, where $ f_{m} $ is the highest frequency in the signal. Since a cosine has only one positive frequency, for a cosine $ f_{m}=f $ and the nyquist rate is $ f_{s}=2 f \ Hz $.

For demonstration, consider a cosine with frequency 880 Hz. This represents a pure A note. This signal can be written as: $ x(t)=cos(2 \pi 880 t) $

In continuous time, the signal looks like this:

signal

Using the continuous time signal, it is possible to sample the signal. Due to the Nyquist Theorem, $ f_{s}>1760\ Hz $. To demonstrate sampling above the Nyquist Rate, a $ f_{s} $ of 2000 Hz will be used. The sampling points are shown in red on top of the original signal below

Sampling

CTFT vs DTFT

In order to understand what is happening in the frequency domain, we can compare the CTFT of the cosine to the DTFT of the sampled cosine.

From the CTFT table, the CTFT of a Cosine is

$ X(f)=\frac{\delta(f-880)+\delta(f+880)}{2} $

CTFT

To obtain the DTFT from the CTFT, three steps must occur:

  • Rescale the frequency axis: $ \chi(\omega) = X(\frac{\omega f_{s}}{2 \pi }) $
  • Rescale the magnitude by 1/T
  • Repeat ("rep") the signal every $ 2 \pi $

Sampling above the nyquist rate

For the sampling at 2000Hz, this results in the following DTFT:

$ \Chi(\omega)=2000\frac{\delta(\frac{2000 \omega}{2 \pi }-880)+\delta(\frac{2000 \omega}{2 \pi }+880)}{2}, -\pi<\omega<\pi $

$ \Chi(\omega)=2000\frac{\delta(\frac{2000 \omega-2 \pi 880}{2 \pi })+\delta(\frac{2000 \omega+2 \pi 880}{2 \pi })}{2}, -\pi<\omega<\pi $

$ \Chi(\omega)=2000\frac{\delta(2000\frac{ \omega-2 \pi \frac{880}{2000}}{2 \pi })+\delta(\frac{2000\omega+2 \pi \frac{880}{2000}}{2 \pi })}{2}, -\pi<\omega<\pi $


$ \Chi(\omega)=2\pi \frac{\delta( \omega- \pi \frac{880}{1000})+\delta(\omega+\pi \frac{880}{1000})}{2}, -\pi<\omega<\pi $

$ \Chi(\omega)=\pi \delta( \omega- \pi \frac{880}{1000})+\pi \delta(\omega+\pi \frac{880}{1000}), -\pi<\omega<\pi $

$ \Chi(\omega)=\left\{\begin{array}{ll}\pi \delta( \omega- \pi \frac{880}{1000})+\pi \delta(\omega+\pi \frac{880}{1000}), & \text{ if }-\pi<\omega<\pi,\\ \text{periodic period } 2\pi\end{array} \right. \ $

Sampling Above Nyquist


Sampling Below the Nyquist Rate

We can repeat the same process for a sampling below the Nyquist rate. In this case, we will sample at 1000 Hz. Using the same process as above, the result is:

$ \Chi(\omega)=\left\{\begin{array}{ll}\pi \delta( \omega- \pi \frac{880}{500})+\pi \delta(\omega+\pi \frac{880}{500}), & \ ,\\ \text{periodic period } 2\pi\end{array} \right. \ $

$ \Chi(\omega)=\left\{\begin{array}{ll}\pi \delta( \omega- \pi \frac{120}{500})+\pi \delta(\omega+\pi \frac{120}{500}), & \text{ if }-\pi<\omega<\pi,\\ \text{periodic period } 2\pi\end{array} \right. \ $

The plot of the DTFT is shown below:

Sampling Below Nyquist

Note that the original frequency components are outside of the $ [-\pi,\pi] $ range. This leads to aliasing, which creates an additional frequency component at 120 Hz. This illustrates the fact that sampling below the nyquist rate will create aliasing and prevent shannnon reconstruction of the signal.


Conclusion

As a brief overview, there are two main takeaways:

  • The DTFT can be obtained from the CTFT by time scaling f by $ 2\pi/f_s $, magnitude scaling by $ f_s $, and repeating every $ 2\pi $
  • Sampling below the nyquist rate will cause aliasing and add low frequency components to the signal, potentially preventing any recovery.


Questions and comments

If you have any questions, comments, etc. please post them on this page.


Back to ECE438 slectures, Fall 2014

Alumni Liaison

Prof. Math. Ohio State and Associate Dean
Outstanding Alumnus Purdue Math 2008

Jeff McNeal